top of page

 CURRENTLY IN DEVELOPMENT. FOR MORE INFO CONTACT: info@perceptivesensors.com

TANK

MONITORING

REAL-TIME VERIFICATION

EXTERIOR-MOUNTED GAUGES PERFORM THE FOLLOWING: 

Monitor Degradation

Detection of Fluids

Detection of No Fluid

Self Testing Units

Independent Powered

Redundant Communications

SCADA Interface

Independent Cell Alarm

a_SlideBG_TFbg_BLUGRY.jpg

MILLIONS OF GALLONS MONITORED in REAL-TIME

One Tank Farm

THE INSIDE LOOK - THE WHY

All Liquids have a Unique Acoustic Fingerprint. Liquids can be monitored using non-invasive acoustic technology for material degradation, fluctuation in blend (ex. 87 to 86.9 Octane), over any length of time regardless of temperature or separation. 

​

ULTRASONIC TECHNOLOGY - THE HOW

In the instances involving large drums (ie. Large Tanks, Tankers, Oil Drums,etc.)

Orientation, Alignment is Critical, but essential ultrasonic energy travels through the container wall-liquid-wall configuration and is received by a transducer.

​

SINGLE TRANSDUCER

(PULSE-ECHO MODALITY)

DUAL TRANSDUCER

(PITCH-CATCH MODALITY)

Ultrasonic_PulseOnly_Orange.png
TanktoTank_DkBlue.png
Ultrasonic_PulseEcho_Orange.png
Ultrasonic_PulsePitchCatch_Orange.png

Sound field is modified by the container walls and the liquid where density, viscosity, elasticity, compressibility, and temperature play key roles in influencing the velocity and relative attenuation

​

MODEL SERIES PT300

Units are available with optional extended internal / removable battery or solar-powered.

TransferIcons_Battery.png
WiFi_Icon_DkBlue.png
TransferIcons_DimensionsBL.png

Solar-Powered, Hardwired (w/ UPS battery or Internal Battery (6 to 12 month lifespan).

Bluetooth™ Enabled, Cellular or Satellite Commnication (or any combination thereof).

Small Footprint (laptop sized), Surface Mounted (externally).

​

TankUnitMounted.png
aOilTank_3DModel_Steps_v2_15PERCENT.png

Constant / Redundant Monitoring at Every Level.

A Series of Perceptive Sensor Model Series PT300* Units at key installed at levels of a tank. Content, even vacancy detection alerts are active with (opt) Actionable Intelligence in real-time.

​

SENSOR 5

HIGH-HIGH LEVEL

SENSOR 4

HIGH LEVEL

TankUnitMounted.png
FCT_Controller.png
Cloud_ORG.png
FCT_CellPhone.png

On-site units collect data, determine content / status and transmit readings.

​

SoundData™ is collected and decifered. Database is updated and sequenced.

​

Reports issued real-time to field management at preset conditional stages.

​

iPhone_ScreenSamplesCase_OverfillHIGHHIG

MAXIMUM CAPACITY

Pinpoint accuracy provided by HIGH-HIGH sensor allows additional 5-10% Capacity and Actionable Intelligence assigned to activate on pos / neg reading (ex. SCADA Interface; Emergency Notifications via cell and other functions)

​

bottom of page