top of page

 CURRENTLY IN DEVELOPMENT. FOR MORE INFO CONTACT: info@perceptivesensors.com

TANK

MONITORING

REAL-TIME VERIFICATION

EXTERIOR-MOUNTED GAUGES PERFORM THE FOLLOWING: 

Monitor Degradation

Detection of Fluids

Detection of No Fluid

Self Testing Units

Independent Powered

Redundant Communications

SCADA Interface

Independent Cell Alarm

a_SlideBG_TFbg_BLUGRY.jpg

MILLIONS OF GALLONS MONITORED in REAL-TIME

One Tank Farm

THE INSIDE LOOK - THE WHY

All Liquids have a Unique Acoustic Fingerprint. Liquids can be monitored using non-invasive acoustic technology for material degradation, fluctuation in blend (ex. 87 to 86.9 Octane), over any length of time regardless of temperature or separation. 

ULTRASONIC TECHNOLOGY - THE HOW

In the instances involving large drums (ie. Large Tanks, Tankers, Oil Drums,etc.)

Orientation, Alignment is Critical, but essential ultrasonic energy travels through the container wall-liquid-wall configuration and is received by a transducer.

SINGLE TRANSDUCER

(PULSE-ECHO MODALITY)

DUAL TRANSDUCER

(PITCH-CATCH MODALITY)

Ultrasonic_PulseOnly_Orange.png
TanktoTank_DkBlue.png
Ultrasonic_PulseEcho_Orange.png
Ultrasonic_PulsePitchCatch_Orange.png

Sound field is modified by the container walls and the liquid where density, viscosity, elasticity, compressibility, and temperature play key roles in influencing the velocity and relative attenuation

MODEL SERIES PT300

Units are available with optional extended internal / removable battery or solar-powered.

TransferIcons_Battery.png
WiFi_Icon_DkBlue.png
TransferIcons_DimensionsBL.png

Solar-Powered, Hardwired (w/ UPS battery or Internal Battery (6 to 12 month lifespan).

Bluetooth™ Enabled, Cellular or Satellite Commnication (or any combination thereof).

Small Footprint (laptop sized), Surface Mounted (externally).

TankUnitMounted.png
aOilTank_3DModel_Steps_v2_15PERCENT.png

Constant / Redundant Monitoring at Every Level.

A Series of Perceptive Sensor Model Series PT300* Units at key installed at levels of a tank. Content, even vacancy detection alerts are active with (opt) Actionable Intelligence in real-time.

SENSOR 5

HIGH-HIGH LEVEL

SENSOR 4

HIGH LEVEL

TankUnitMounted.png
FCT_Controller.png
Cloud_ORG.png
FCT_CellPhone.png

On-site units collect data, determine content / status and transmit readings.

SoundData™ is collected and decifered. Database is updated and sequenced.

Reports issued real-time to field management at preset conditional stages.

iPhone_ScreenSamplesCase_OverfillHIGHHIG

MAXIMUM CAPACITY

Pinpoint accuracy provided by HIGH-HIGH sensor allows additional 5-10% Capacity and Actionable Intelligence assigned to activate on pos / neg reading (ex. SCADA Interface; Emergency Notifications via cell and other functions)